![]() It doesn't vent to the atmosphere when the system reaches 15 psi. The vent doesn't need to be at the highest point in the system because it's a completely closed air-tight system. It came that way from the factory, and if you don't install a vented design cap you will over-pressurize your coolant system and you will crack your radiator, or blow off a hose. Labbe001: Your radiator cap MUST be a venting design. Where the heck do you get your information from? If it drops down at all it is the wrong cap. if you get a cap and hold it with the disk down it should stay tight against the rubber seal. The spring is weak enough that as the system cools the coolant can easily be pulled past and back into the system.īottom line. If this spring loaded type is NOT used then any small leak in the system that would allow any air to leak in would let the coolant flow out and into the overflow tank since it is a low point in the system. The Fiero needs the spring loaded disk so that the disk is held closed all the time. The loose type is used when the radiator cap is a high point in the system since coolant expansion will push the disk closed. One that is just a loose disk and one that is spring loaded to hold it closed. the small metal disk is actually the "vent". That is not "venting" that is just working pressure. All caps are spring loaded to relieve at their rated pressure. Or, the transfer pump is made larger without a thought about the tank vent size.Īll tanks should have both vents and overflows.pressure protection devices will be required for some types of service.In my mind the biggest difference is the small metal vent disk that is in the middle of the cap. spills and other accidents commonly occur when maintenance staff or uncaring plant management take a tank or group of tanks from one service to another without a complete and detailed evaluation of all of the tank features. ![]() Ultimately, the configuration of tank vents, drains and overflows must be based on the PARTICULAR LIQUID SERVICE as well as the rules and regulations to which the tank must comply !!! Sulfuric acid tank vents and overflows are sized and configured completely different that fuel oil tanks. The purpose of an overflow is to also protect the tank ( sheell/roof joint) by limiting the maximum liquid level The purpose of the vent is to protect the tank during filling and emptying operataions and should be sized based on the flow rate and liquid characteristics. I was trying to convey what I have commonly seen on fuel oil tanks. I was not trying to recommend, endorse or suggest any particular type of vent/overflow configuration. Overfills need to be discharge to the secondary containment around the tank or to a discharge tank. In all cases, the vents need to be placed in a location where that will not allow vapors from accumulating in a space therefore, we want some means to safely discharge the vapors. This is only used on non-volatile containing tanks.Ģ- A conservator vent allows the tank to breathe in and out but limits or restricts vapors from escaping. ![]() Therefore, never fill a tank to 100% but 95%.ġ- A free breathing vent is located at or near a reasonable high part of the tank or roof and allows the tank to breath in and out. In some cases, 95% is 100%.in other words when the tank liquid is pumped in at 90F to about the 95% level that should be alarmed then the tank heats up from the hot sun or hot weather and swells to near 100%. ![]() The over flow is strictly this, a means of discharging the tank when the tank capacity has been reached. When distinguishing between a vent and an over-fill I would like to clarify further.Īn overfill or overflow opening is located at the 100% of the tank capacity. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |